Hey everyone, it’s Mia here from your go-to Electric Refrigeration Unit supplier—so today I’m breaking down something we get asked all the time: how to replace the compressor in one of our units. Let’s be real, a dead compressor is like the heart stopping in your fridge or cold box—nothing works without it. I’ve seen techs mess this up because they skip a step or grab the wrong part, so I’m laying this out step-by-step like I’m talking to a buddy who’s got a side gig fixing fridges. No fancy jargon, just real stuff we’ve tested on hundreds of our units over the years. Electric Refrigeration Unit

First off, let’s get one thing straight: this is for our standard electric refrigeration units, not like industrial walk-ins that need a whole crew—wait, no, actually even for the smaller ones, safety comes first. I can’t stress that enough. Last quarter, a local tech skipped unplugging the unit and nicked a live wire, fried himself, and our replacement compressor too. Don’t be that guy. Before you even touch a tool, turn off the main power breaker to the unit. Lock it out if you can—tag it too, so no one accidentally flips it on while you’re under there. Also, grab your PPE: work gloves, safety glasses, even closed-toe shoes. Compressors are heavy, and the lines are sharp when you cut ‘em. Trust me on that.
Next, you gotta diagnose it first. Wait, why? ‘Cause sometimes it’s not the compressor. Our customer service line gets calls like “my unit isn’t cooling—send a compressor” and then it’s just a bad thermostat or a tripped high-pressure switch. So grab a multimeter (we recommend Fluke 117 for this, it’s the one we keep in every service van) and test the compressor terminals. You should get a consistent resistance reading—if it’s infinite, that means the windings are burnt out, and if it’s zero, it’s shorted. That’s when you know for sure it’s the compressor, not something else. Also, check the amp draw on the compressor motor—if it’s way above what’s listed on the unit’s spec sheet (you can find that on the model tag we put on every unit, no need to hunt), that’s another dead giveaway.
Okay, so you’re positive it’s the compressor. Now, time to pull the old one out. First, drain the refrigerant. Don’t just cut the lines and let it vent—refrigerant is bad for the environment, and it’ll get in your lungs if you’re not careful. You need a recovery machine—again, this is a must, don’t skip this. Connect the recovery lines to the service ports on the unit, turn on the machine, and let it suck all the old refrigerant into the recovery tank. How long does this take? Usually 15-20 mins for our smaller residential and light-commercial units, a bit longer for the bigger ones. While that’s going, take notes on how everything is wired. I always take a pic with my phone of the wiring connections on the compressor—colors can get mixed up, and miswiring is the #1 mistake we see when people replace their own compressors. Don’t rely on memory, ‘cause you’ll forget by the time you’re done.
Once the refrigerant’s fully recovered, you can cut the lines. Use a tubing cutter, not a hacksaw—hacksaw leaves burrs that’ll leak later, and we warranty our compressors, but not for stupid leaks. Cut the lines as close to the compressor as possible, leaving enough length to work with the new unit. Then, remove the mounting bolts that hold the compressor in place. Most of our compressors are mounted on rubber pads to reduce vibration, so there’ll be four bolts (usually) holding it down. Loosen those, wiggle the old compressor out—they’re heavy, so lift with your legs, not your back. I’ve seen a tech throw his back out ‘cause he tried to lift a 50lb compressor one-handed. Don’t do that.
Now, the fun part: installing the new compressor. First, make sure you got the right one. This is non-negotiable. Every compressor we sell is matched to the exact model of our electric refrigeration unit, based on BTU rating, voltage, and phase. If you grab a compressor with a different BTU, it’ll overcool or undercool, and you’ll be back here in a week. Double-check the part number on the old compressor—write it down, send it to our parts team if you’re not sure, they’ll confirm it for you. We don’t want you ordering the wrong part, ‘cause we’re here to make this easy, not add more work.
Before you put the new compressor in, replace the rubber mounting pads. Those pads wear out over time, and if you skip this, the new compressor will vibrate like crazy, which can damage the lines and shorten the new compressor’s life. Also, clean the area where the compressor sits—no dust, no old refrigerant residue, that’ll mess with the seals. Then, set the new compressor in place, tighten the mounting bolts just enough so it doesn’t move, but not so tight that you crack the compressor’s shell.
Next up, connecting the lines. First, deburr the cut lines with a reamer—super important, burrs cause leaks. Then, flaring the lines if they’re copper (most of our units have copper lines). If you’re not comfortable flaring, you can use compression fittings, but make sure they’re the right size. But for our standard installs, flaring is better for a tight seal. Then, connect the lines to the new compressor’s service ports. Tighten the fitting with a wrench—don’t over-tighten, that’ll strip the threads. Again, double-check that the lines aren’t kinked, that’ll restrict flow and kill the cooling.
Now, wiring. This is where that pic you took earlier comes in. Connect the wires to the new compressor’s terminals exactly how they were on the old one. If you’re working on a single-phase unit, that’s easier—there’s usually three wires: power, common, and start. Three-phase is a little trickier, but again, the pic saves you. Use wire nuts that are the right size, and wrap electrical tape around the connections so they don’t come loose. Make sure none of the wires are touching the compressor shell or the metal frame of the unit—short circuit is the last thing you want here.
Now, we gotta evacuate and recharge the system. This is another step that people skip, and it’s why their new compressor dies fast. Evacuation removes all the air and moisture from the lines. Connect the vacuum pump to the service ports, run it for at least 30 mins (for our smaller units, bigger ones need 45 mins). You want the vacuum gauge to read at least 500 microns—if it’s higher than that, there’s still moisture, and that’ll cause acid in the system, which eats up the compressor internals.
Once evacuation is done, you’re ready to charge the refrigerant. How much? Check the spec tag on your unit—every one of our units has the exact refrigerant charge amount listed, no guessing. Use the same type of refrigerant that was in the old unit (you should have recovered it, right? If you didn’t, don’t grab the wrong one—call our tech support line, they’ll tell you which you need). Charge it slowly, don’t overfill, ‘cause overcharging is as bad as undercharging. Once it’s charged, turn on the power, and let it run for 30 mins. Check the pressure gauges—low side should be around 20-30 PSI for most of our units, high side around 150-200 PSI. If that’s off, you messed up the charge, so adjust it.
Wait, but before you call it done, leak test everything. Use soapy water—spray it on all the line connections, service ports, where the compressor is mounted. If you see bubbles, that’s a leak. Tighten the fitting a little more, or re-flare the line if it’s a bad leak. Don’t leave leaks—refrigerant will escape, and your new compressor will overheat and die in no time.
Let’s talk about common mistakes I see techs make all the time. First, not replacing the drier filter. Every time you open the system to replace a compressor, you gotta replace the drier filter. The old one has moisture and debris from the dead compressor, and if you leave it, it’ll clog the lines or go into the new compressor and ruin it. We sell drier filters for all our units, so grab one when you order the compressor. Second, rushing the evacuation step. I’ve had techs run it for 10 mins and then wonder why the compressor died in two weeks. Take the time—30 mins minimum, that’s not optional. Third, mismatching the compressor. Don’t think “a higher BTU compressor will cool better”—no, it’ll cycle on and off too much, burn out fast. Stick to the exact part number for your unit.
Now, warranty stuff. All our compressors come with a 2-year warranty, but only if they’re installed correctly. So if you follow these steps, you’re covered. If you skip a step and it breaks, well, that’s on you. But trust me, these steps are easy, and we’ve tested them on thousands of our units.
Wait, who is this for? If you’re a DIYer with some basic tool skills, this is doable. But if you’ve never worked with refrigerant or electrical stuff, call a licensed HVAC tech. Refrigerant is regulated in most places, and electrical work can be dangerous. We don’t want anyone getting hurt, so know your limits.
And that’s basically it—replacing the compressor in one of our electric refrigeration units. It’s not rocket science, but it’s not something you wanna half-ass. Take your time, follow the steps, double-check everything, and you’ll have your unit up and running again in a few hours.

If you need a new compressor, or you’re not sure if you should replace it, hit up our team. We can confirm the part number over the phone, answer any questions, and even connect you with a local tech if you don’t wanna do it yourself. We’re here to make sure your refrigeration unit works right, no stress. Don’t hesitate to reach out for any help with your Electric Refrigeration Unit—we’ve got your back.
Refrigeration Unit REFERENCES
- ASHRAE Handbook: Refrigeration Systems and Applications, 2022
- EPA Section 608 Technician Certification Guidelines for Refrigerant Recovery, 2021
- Electric Refrigeration Unit Compressor Replacement Procedures: Manufacturer Best Practices, 2023
Xinxiang Coworld Refrigeration Technology Co., Ltd.
As one of the most professional electric refrigeration unit manufacturers and suppliers in China, our products have good reputation in the market. We warmly welcome you to buy cheap electric refrigeration unit for sale here from our factory. If you have any enquiry about cooperation, please feel free to email us.
Address: B103 ROOM, GT CITY, NO.199 ZHENGZHONG ROAD, HIGH TECH ZONE, XINXIANG CITY, HENAN PROVINCE, CHINA
E-mail: coworldfrio@hotmail.com
WebSite: https://www.coworldthermo.com/